What is a Variable Frequency Drive? 
		 
		
			 
		 
		
			A variable frequency drive is an electronic device that allows you to start, stop, and control the speed of a three phase motor. It is also a motor starter as it is equipped with overload protection. Read more »  
				 
		 
	 
	
		
			What is the difference between a 'new surplus' motor and a 'factory new' motor? 
				 
		 
		
			 
		 
		
			Our New Surplus electric motors and drives are new and unused overstock or discontinued items offered at lower prices and come with our 90-day warranty. 
				 
				Factory New products are competitively priced and come with a manufacturers warranty. 
				 
		 
	 
	
		
			Variable frequency drives (VFDs or inverters) now play an important part in major industry. 
		 
		
			 
		 
	 
	
		
			Within the last 10 years they have been perfected to control and vary the speed of 3 phase electric motors. They serve many purposes, besides speed control. Homeowners and hobbyist alike, who have lathes or milling machines with a 3 phase motor, usually don't have 3 phase power to operate. These VFDs (instead of using a rotary phase converter) can now be used to convert single phase power to 3 phase power. Read more »  
		 
	 
 
								     
							     
							    
                            
                            
                          
					
				 
						
				
				
				 
 
 
 
				
				
                
			
		 	 		
	
		
			
						 			  						
				
	
		5 HP, 3600 RPM, 460 Volts, TEFC, 184TC, IEEE841, FOOTED, PREMIUM, TECO, HB0052C  		 
	 
				
											 
				 
	
		HB0052C  
	 
	
		  	 
	
							 
	 
			
			  		 	
	   	
		
			
				
				
					
						
							
								MAX-E2/841 SEVERE DUTY / INVERTER DUTY AEHH8BCF, C-FACE, NEMA PREMIUM IEEE841 [HB] APPLICATIONS: Fans and Blowers Pumps Crushers Compressors Mixers Conveyors Severe Duty/Petro Chemical Pulp and Paper Application Marine Duty FEATURES:    Output:  5 HP     Speed:  3600 RPM     Voltage:  460 Volts @ 60 Hz     Frame:  184TC     Full Load Efficiency:  88.5%     Full Load Power Factor:  92.5%     Full Load Amperage:  5.72A      Enclosure:  Totally Enclosed Fan Cooled (IP56)     Service Factor:  1.15 (Continuous); (1.0 @ 50 Hz)      Meets or Exceeds IEEE 841 Standards       Meets IEEE 45 Marine Duty and ABS Design Assessment up to 150 HP       Extended Warranty:  60 Months from Date of Manufacture     Insulation:  Class F     Temperature Rise:  Class B      NEMA Design B Torques as a Minimum; Various Ratings also Meet Design C      Construction:   Cast Iron Frame      End Brackets & Fan Cover and Main Conduit Box      (F# 5000 and with Larger with Pressed Steel Plate Main Conduit Box.)       Grounding Terminal:  Inside Main Conduit Box with additional Foot Grounding Provision     Conduit Box:   Oversized and Rotatable in 90 Degree Increments - F1 Mounted     Ambient Temperature:   Designed for 50°C     Elevation:   Designed for 3300 ft.     Rotation:   Bi-Directional; Except 2 Pole "Hybrid" and F# 5000 and Larger Ratings are Counter-Clockwise facing the DE     Shaft:  1045 Carbon Steel     Rotor Construction:  Aluminum Die Cast Squirrel Cage for F# 140T - 449T     Rotor Construction:  Copper/Copper Alloy for F# 5000 and Larger     (F# 5007 - 5011 8 Pole Ratings are Aluminum Die Cast Squirrel Cage Rotor Construction)       Paint System:  2 Part Epoxy      Paint Color:  Blue - Munsell 5PB 3/8     Bearings:  High Quality Ball (or Roller)  Regreasable with Mobil Polyrex™ EM Grease      Automatic Grease Discharge Fittings       VBXX INPRO™ Seals Installed on Both Ends       Stainless Steel Nameplate and Hardware       Stainless Steel Automatic Breather Drain       Suitable for Inverter Duty (PWM - Pulse Width Modulation) per NEMA MG-1 Part 30(4 & 5)       Inverter Duty Speed Range:  20:1 Variable Torque / 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)     Motor service factor is 1.0 when operated on a VFD.       Motors are U.L. Recognized CSA Approved       3 Leads Only       Dual Drilled Feet Available on Most Ratings - Longer Frames (i.e. 145T Drilled also for 143T)       Vibration Not to Exceed 0.08 Inches Per Second       Noise Level Not to Exceed 85 dB(A) at 1 Meter Unloaded       CSA Certified for Class I  Div. 2  Groups B  C  D - Temp Code T3 Maximum       CSA Certified for Class II  Div. 2  Groups F & G - Temp Code T3 Maximum (Frame 444T and Above)      Catalog# HB3502 & HB3504 are "Hybrid" ratings; Not CSA Certified (Self-Certify Only) for hazardous locations       and not dual drilled.      Catalog# HB3006 also not CSA Certified for hazardous locations (Self-Certify Only).      Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1.  Note: Stock catalog image shown.  Actual motor may differ. 
 
							 
						
					 
				 
				
				
 
			 
		 
	 
 
 	
	
 
 
	 
 
	
    
	
					
			
				
	
	
	
		
		
		
			
			
			Dealers Industrial Equipment, LLC 619 Ramsey Avenue Hillside, NJ 07205  
				
				
				 Toll Free:  800-469-3110  Phone: 908-688-1966 Fax: 908-688-1844  
					
					
					Email: srelaed@gmail.com 
					
					
					 **After Hours Emergency Phone: 732-428-9677**  
			
			
			©Copyright Dealers Industrial Equipment, LLC 2023