What is a Variable Frequency Drive?
A variable frequency drive is an electronic device that allows you to start, stop, and control the speed of a three phase motor. It is also a motor starter as it is equipped with overload protection. Read more »
What is the difference between a 'new surplus' motor and a 'factory new' motor?
Our New Surplus electric motors and drives are new and unused overstock or discontinued items offered at lower prices and come with our 90-day warranty.

Factory New products are competitively priced and come with a manufacturers warranty.
Variable frequency drives (VFDs or inverters) now play an important part in major industry.
Within the last 10 years they have been perfected to control and vary the speed of 3 phase electric motors. They serve many purposes, besides speed control. Homeowners and hobbyist alike, who have lathes or milling machines with a 3 phase motor, usually don't have 3 phase power to operate. These VFDs (instead of using a rotary phase converter) can now be used to convert single phase power to 3 phase power. Read more »
 
 
F510-4250-C3-Dealers Electric-Teco
View Larger
0 Star Rating
0.0
 (Be the first to Write a Review)
 
    
 

250 HP, 460 Volts, IP 20, Teco, F510-4250-C3


Discontinued - replaced by F510-4250-C3-UE
Model #: F510-4250-C3-U  
460 Volts 3 Phase Input, 460 Volts 3 Phase Output
 
Stock:  0
HP : 250
Enclosure : IP 00
Input Voltage : 460
Input Phase : 3
Manufacturer : Teco-Westinghouse
Output Voltage : 460
Output Phase : 3
Model : F510
Item Condition : Factory New
Weight:  195 lbs
Retail Price$18,580.00
Add to Cart for Price
 
Out of Stock

Teco F510 Fan and Pump AC Drive
Factory New

The F510 Fan and Pump AC Drive is an easily configured and versatile drive product that will control almost any application involving fans, blowers, and centrifugal pumps. It comes standard with a simple-to-select preset application parameter for commonly applied fan and pump applications.

Replacement for the MA7200 Series Variable Torque Application.

Specifications

  • Input Voltage: 460 Volt 3 Phase
  • Output Voltage: 460 Volt 3 Phase
  • Constant Torque Horsepower: -
  • Constant Torque Amps: -
  • Variable Torque Horsepower: 250
  • Variable Torque Amps: 328
  • Enclosure: IP00 (chassis-rated) NEMA 1 kit JN5-NK-07 is available for purchase
  • Additional Features: Built in DC Link Reactor
  • Height: 31.1"
  • Width: 18.08"
  • Depth: 12.78"
  • Warranty: Factory New with Manufactures Warranty

Features

  • Built-in pump cascade control for up to 4 pumps
    • Option card for control of up to 8 pumps
  • Two separate PID loop controls
    • Switch between PID loops based on input signal or real-time clock setting
  • Extensive monitoring and display capabilities
  • Real time clock built-in (RTC)
  • Conformal coating of all printed circuit boards (non-hazardous)
  • Plenum Rated
  • Built-in Modbus RTU, BACnet MS/TP, or Metasys (N2) communications via on-board RS485 or RJ45 connection
  • Built-in PLC functionality
  • Scalable process parameters to engineering units
  • Digital I/O
    • 6 Configurable digital inputs
    • 3 Configurable digital relay outputs
    • Dedicated hardware safety input for user's emergency interface
  • Analog I/O
    • 2 Analog inputs and 2 Analog outputs
  • PTC input - Direct reading of water temperature
  • Pulse input and pulse output signals capable of up to 32 khz
  • 3 modes of auto tuning to best adapt the F510 with the applied motor
  • Controls induction or permanent magnet motors
  • 100 Mhz RISC process for ultra-high speed computations and rapid loop-time updates

Applications:

Ideal product for fan and centrifugal pump applications:
  • HVAC
  • Cooling Towers
  • Irrigation
  • Wastewater Industries
  • Industrial Pumping
Characteristics
Control
Characteristics
Operation Mode LCD Keypad with Parameter Copy Function
Control modes Volts/Hz (V/F), Sensorless Vector (SLV),
Sensorless Vector with Permanent Magnet Motor (PMSLV)
Frequency control range 0.1Hz ~ 400.0Hz
Frequency accuracy
(Temperature change)
Digital references: ±0.01% (-10~+40ºC),
Analog references: ±0.10% (25ºC ±10ºC)
Speed control accuracy ±0.5% (sensorless vector mode)
Frequency setting
resolution
Digital references: 0.01Hz,
Analog references: 0.06Hz/60Hz
Output frequency
resolution
0.01Hz
Overload tolerance rated
output current
120%/1 min
Frequency setting signal 0 ~ +10VDC/ -10VDC ~+10VDC or 4~20mA,
digital presets, RS485 communications and pulse–type frequency command
Acceleration/
deceleration time
0.0~6000.0 sec (separately set acceleration and deceleration times)
Voltage, frequency
characteristics
Preset V/F menu can set custom V/F-curve based on parameters
Braking torque Approximately 20%
Main control functions Auto tuning, droop control, soft-switching in PWM, over voltage protection,
dynamic braking, speed search, instantaneous power fault restart,
two sets of PID control, slip compensation, RS485 communicaton Modbus RTU,
METASYS (N2), or BACnet MS/TP standard, speed feedback control,
simple PLC functionality, two sets of analog output, safety switch interlock
Additional control
functions
Record of elapsed power-up and operation times, 4 most recent occurrences
of faults and the most recent fault record status, energy-saving function
setting, phase loss protection, smart braking, DC braking, dwell,
S-curve acceleration and deceleration, Up/ Down operation, energy meter,
pulse output, engineering unit display, Local/ Remote switching key,
SINK/ SOURCE input interface options
Protection Features Stall protection Threshold current can be set. (In acceleration or constant speed, it
can be set separately. In deceleration it can be set on or off)
Instantaneous Over Current
(OC) and output Short
Circuit (SC) protection
Inverter shuts off when the current exceeds 160% of the inverter rated current.
Inverter Overload
protection (OL2)
Inverter rated current is 120%/1 min. Inverter shuts off when the
current is higher than 120% of the rated current for 1 min.
Default carrier frequency factory setting is 2-4 kHz.
Motor Overload (OL1)
protection
Electrical overload protection curve
Over Voltage (OV)
protection
When the main circuit DC voltage exceeds 410V (230V units)/ 820V
(460V units), the drive faults out regardless of whether it is in run
mode or stopped.
Under Voltage (UV) When the main circuit DC voltage is under 190V (230V units)/ 380V
(460V units), the drive faults out regardless of whether it is in run
mode or stopped. The DC voltage trigger level can be adjusted.
Automatic restart after
instantaneous power fault
Power fault exceeds 15 ms. This is programmable to 2 seconds.
Overheat protection (OH) By direct temperature detection in the unit
Ground Fault
protection (GF)
Uses current feedback for protection
Protection in charge state When main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.
Output Phase Loss
protection (OPL)
Automatically stops motor rotation and faults
Environmental
Specifications
Location Indoor (protected from corrosive gases and dust) Plenum Rated
Ambient temperature 10~+40°C without derating (IP20/NEMA1), -10~+50°C (IP00), with
derating, its maximum operation temperature is 60°C
Storage temperature -20~+70°C
Humidity 95%RH or less (no condensation)
Altitude and vibration Altitude of 1,000 m (3,300 ft) or lower, vibration below 5.9 m/s2 (0.6G)
Functions Communication function RS485 standard with built-in (MODBUS/ BACNet/ Metasys N2) (RJ45)
PLC function Built-in
Certifications/
Compliance
EMI protection The optional added noise filter complies with EN61800-3; 460V, 75 hp or
below can be built-in (call for details).
EMS protection Follows EN61800-3
 Average Rating:  0 Star Rating