A variable frequency drive is an electronic device that allows you to start, stop, and control the speed of a three phase motor. It is also a motor starter as it is equipped with overload protection. Read more »
What is the difference between a 'new surplus' motor and a 'factory new' motor?
Our New Surplus electric motors and drives are new and unused overstock or discontinued items offered at lower prices and come with our 90-day warranty.
Factory New products are competitively priced and come with a manufacturers warranty.
Variable frequency drives (VFDs or inverters) now play an important part in major industry.
Within the last 10 years they have been perfected to control and vary the speed of 3 phase electric motors. They serve many purposes, besides speed control. Homeowners and hobbyist alike, who have lathes or milling machines with a 3 phase motor, usually don't have 3 phase power to operate. These VFDs (instead of using a rotary phase converter) can now be used to convert single phase power to 3 phase power. Read more »
AEGH, FOOTED, NEMA PREMIUM WITH AEGIS SHAFT GROUNDING RING[GP_G]
APPLICATIONS:
Fans & Blowers
Compressors
Pumps
HVAC Equipment
AEGIS SHAFT GROUNDING RING
The AEGIS® SGR Bearing Protection Ring prevents electrical bearing fluting damage by safely diverting harmful shaft voltages and bearing currents to ground. Using proprietary Electron Transport Technology™, the conductive microfibers inside the AEGIS® SGR provide the most reliable current diversion technology for shaft grounding with a "path of least resistance" to dramatically extend motor life. AEGIS® SGR Rings have a warranty of 1 year.
FEATURES:
Output: 2 HP
Speed: 3600 RPM
Voltage: 208/230/460 Volts @ 60 Hz
Frame: 145T
Full Load Efficiency: 86.5%
Full Load Power Factor: 85%
Full Load Amperage: 5.09A
Enclosure: Totally Enclosed Fan Cooled (IP44)
Service Factor: 1.15 (Continuous); (1.0 @ 50 Hz)
Grounding Ring Factory Installed Externally on non drive end (NDE) bracket
Insulation Class: F
Temperature Rise: Class B
NEMA Design B Torques
Construction: Rolled Steel Frame
Fan Cover
and Main Conduit Box
Grounding Terminal: Inside Main Conduit Box
Conduit Box: Oversized Main Rotatable in 90 Degree Increments - F1 Mounted Only (F2 not available)
Ambient Temperature: Designed for 40°C
Elevation: Designed for < 3300 ft.
Rotation: Bi-Directional
Construction: Cast Iron End Brackets
Shaft: 1045 Carbon Steel
Rotor Construction: Aluminum Die Cast Squirrel Cage
Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
Paint Color: Blue - Munsell 5PB 3/8
Bearings: Double Shielded Pre-Packed with MULTEMP SRL (Non-regreasable)
Nameplate: Stainless Steel
Suitable for Inverter Duty (PWM - Pulse Width Modulation) per NEMA MG-1 Part 30(3; 4)