What is a Variable Frequency Drive?
A variable frequency drive is an electronic device that allows you to start, stop, and control the speed of a three phase motor. It is also a motor starter as it is equipped with overload protection. Read more »
What is the difference between a 'new surplus' motor and a 'factory new' motor?
Our New Surplus electric motors and drives are new and unused overstock or discontinued items offered at lower prices and come with our 90-day warranty.

Factory New products are competitively priced and come with a manufacturers warranty.
Variable frequency drives (VFDs or inverters) now play an important part in major industry.
Within the last 10 years they have been perfected to control and vary the speed of 3 phase electric motors. They serve many purposes, besides speed control. Homeowners and hobbyist alike, who have lathes or milling machines with a 3 phase motor, usually don't have 3 phase power to operate. These VFDs (instead of using a rotary phase converter) can now be used to convert single phase power to 3 phase power. Read more »
 
 
01036XT3H215T-Dealers Electric-Weg
View Larger
0 Star Rating
0.0
 (Be the first to Write a Review)
 
    
 

10 HP, 3600 RPM, 575 Volts, XPFC, 215T, Footed, Explosion Proof


FREE Ground Shipping
Model #: 01036XT3H215T  
01036XT3H215T
 
In Stock:  Yes
HP : 10
RPM : 3600
Enclosure : XPFC
Frame : 215T
Frame Remarks : Footed
Volts : 575
Phase : 3
Manufacturer : WEG
Classification : Three Phase
Item Condition : Factory New
Model : 14345291
Weight:  216 lbs
Retail Price$1,727.00
Our Price:
$1,543.18
You Save:$183.82 (11%)
Qty: 
 
  • Factory New
  • Output: 10 HP
  • Poles: 2
  • Frequency: 60 Hz
  • Torque: 14.8 lb.ft
  • Voltage: 575 V
  • Frame: 215T
  • RPM: 3510
  • Full Load Amps: 9.28 A
  • Efficiency (100%): 90.2
  • Power factor (100%): 0.90
  • Insulation: F
  • Noise: 72 dB(A)
  • No load current: 2.40 A
  • Locked rotor current (II/In): 6.9
  • Service Factor: 1.15
  • FL Amps @ High: 9.60
  • FL Eff (%): 90.2
  • C Dimension (in): 19.450
Electric Motors
: Hazardous Locations
: Three-Phase : Explosion Proof - NEMA Premium
Catalog Number: 01036XT3H215T
WEG id: 11360151

  • Description

    WEG Explosion Proof motors are suitable for applications requiring UL or CSA certification for hazardous locations. Thermally protected with thermostats, all motors manufactured are submitted to hydrostatic as well as other routine testing at the factory to ensure compliance to the required specifications. WEG NEMA Premium Efficiency Explosion Proof motors are specifically designed to meet or exceed all EPAct requirements for energy efficiency.

  • Applications
    • Petroleum and gasoline
    • Flour / feed mills
    • Grain elevators
    • Fans
    • Pumps
    • Blowers
    • Material handling equipment
    • Other applications requiring motors UL or CSA listed for hazardous locations

  • Standard Features
    • Efficiency Certification number CC029A according to US Department of Energy Regulations
    • Three-phase, 60Hz
    • Voltage: 208-230/460, 460 or 575V
    • Squirrel cage rotor / Aluminum die cast
    • Totally Enclosed Fan Cooled - TEFC (IP55)
    • Ball bearings are supplied as standard
    • Cast iron frame
    • Class 'F' insulation
    • Temperature rise: Class 'B' (80ºC)
    • Service factor: 1.15
    • Inverter Duty as per CSA Standard (LR50962)
    • NEMA dimensions
    • NEMA ratings design 'B'
    • Continuous Duty (S1)
    • 104ºF (40ºC) ambient temperature
    • Altitude: 3300 ft (1000 m)
    • 1045 Carbon Steel Shaft for frames up to 365T
    • 4140 steel shaft for motors 404T and above. (3600 RPM motors supplied with 1045)
    • Class 'F' insulation for all frames
    • Class 'H' impregnation resin
    • F1 mount
    • Stainless steel nameplate
    • Paint: Synthetic Enamel alkyd resin base (exceeds ASTM B117 salt spray test)
    • Color: RAL 5009 - Blue
    • NPT threaded terminal box
    • Non-sparking fan
    • Thermostats
    • Grease fitting from 364T up to 586/7

  • Optional Features - Call Dealers for information on price and availability of optional features
    • Special Voltages and frequency
    • Stainless steel shaft
    • C and D flanges
    • F2 mount

  • NOTES

    Note: Motors are tested according to IEEE 112 std. – method ‘B’ or C390 CSA

  • Design B torque rating on nameplate can be re-plated for design C for 15-200Hp 1800 and 1200 rpm

    Energy efficiency motors verified by UL in addition to the DOE.







    CSA and UL approved




    ALSO ENERGY VERIFIED CSA C390-93(+)
    CSA approved - File LR 50962
    Division I, class I, groups C and D
    Division I, class II, groups F and G

    UL approved - File E 87848
    Temperature code T4
    Frame 143T up to 326T
    Division I, class I, groups C and D
    Division I, class II, grops F and G

    Frame 364T up to 586/7
    Temperature code T3C
    Division I, class I, groups C and D
    Division I, class II, groups F and G*
    * For group G, Service Factor 1.0
  •  Average Rating:  0 Star Rating
    0.0
     
    Write a Review