What is a Variable Frequency Drive?
A variable frequency drive is an electronic device that allows you to start, stop, and control the speed of a three phase motor. It is also a motor starter as it is equipped with overload protection. Read more »
What is the difference between a 'new surplus' motor and a 'factory new' motor?
Our New Surplus electric motors and drives are new and unused overstock or discontinued items offered at lower prices and come with our 90-day warranty.

Factory New products are competitively priced and come with a manufacturers warranty.
Variable frequency drives (VFDs or inverters) now play an important part in major industry.
Within the last 10 years they have been perfected to control and vary the speed of 3 phase electric motors. They serve many purposes, besides speed control. Homeowners and hobbyist alike, who have lathes or milling machines with a 3 phase motor, usually don't have 3 phase power to operate. These VFDs (instead of using a rotary phase converter) can now be used to convert single phase power to 3 phase power. Read more »
 
 
00709XP3E256T-Dealers Electric-Weg
View Larger
0 Star Rating
0.0
 (Be the first to Write a Review)
 
    
 

7.5 HP, 900 RPM, 208/230/460 Volts, XPFC, 256T, Footed, Explosion Proof


Discontinued. Replaced by 00709XT3E256T
Model #: 00709XP3E256T  
00709XP3E256T
 
In Stock:  Yes
HP : 7.5
RPM : 900
Enclosure : XPFC
Frame : 256T
Frame Remarks : Footed
Volts : 208/230/460
Phase : 3
Manufacturer : WEG
Classification : Three Phase
Item Condition : Factory New
Weight:  349 lbs
Retail Price$3,675.00
Our Price:
$4,205.96
Qty: 
 

Product is Discontinued. Replaced by 00709XT3E256T


  • Factory New
  • Output: 7.5 HP
  • Poles: 8
  • Frequency: 60 Hz
  • Torque: 44.4 lb.ft
  • Voltage: 208-230/460 V
  • Frame: 256T
  • RPM: 875
  • Full Load Amps: 24.9-22.5/11.2 A
  • Efficiency (100%): 86.5
  • Power factor (100%): 0.71
  • Insulation: F
  • Noise: 54 dB(A)
  • No load current: 14.5/7.25 A
  • Locked rotor current (II/In): 5.2
  • Service Factor: 1.15
  • FL Amps @ High: 11.2
  • FL Eff (%): 86.5
  • C Dimension (in): 24.923
Electric Motors
: Hazardous Locations
: Three-Phase : Explosion Proof - High Efficiency
Catalog Number: 00709XP3E256T
WEG id: 11933366

  • Description
    WEG Explosion Proof motors are suitable for applications requiring UL or CSA certification for hazardous locations. Thermally protected with thermostats, all motors manufactured are submitted to hydrostatic as well as other routine testing at the factory to ensure compliance to the required specifications.

    WEG High Efficiency Explosion Proof motors are specifically designed to meet or exceed all EPAct requirements for energy efficiency.

  • Applications
    • Petroleum and gasoline
    • Flour / feed mills
    • Grain elevators
    • Fans
    • Pumps
    • Blowers
    • Material handling equipment
    • Other applications requiring motors UL or CSA listed for hazardous locations

  • Standard Features
    • Efficiency Certification number CC029A according to US Department of Energy Regulations
    • Three-phase, 60Hz
    • Voltage: 208-230/460, 460 or 575V
    • 143T up to 586/7 cast iron frame
    • Squirrel cage rotor / Aluminum die cast
    • Totally Enclosed Fan Cooled - TEFC (IP55)
    • Ball bearings are supplied as standard
    • Cast iron frame
    • Class 'F' insulation
    • Temperature rise: Class 'B' (80ºC)
    • Service factor: 1.15
    • Inverter Duty as per CSA Standard (LR50962)
    • NEMA dimensions
    • NEMA ratings design 'B'
    • Continuous Duty (S1)
    • 104ºF (40ºC) ambient temperature
    • Altitude: 3300 ft (1000 m)
    • 1045 Carbon Steel Shaft for frames up to 365T
    • 4140 steel shaft for motors 404T and above. (3600 RPM motors supplied with 1045)
    • Class 'F' insulation for all frames
    • Class 'H' impregnation resin
    • F1 mount
    • Stainless steel nameplate
    • Paint: Synthetic Enamel alkyd resin base (exceeds ASTM B117 salt spray test)
    • Color: RAL 5009
    • NPT threaded terminal box
    • Non-sparking fan
    • Thermostats

  • Optional Features - Call Dealers for information on price and availability of optional features
    • Special Voltages and frequency
    • Stainless steel shaft
    • C and D flanges
    • F2 mount

  • NOTES
    Motors are tested according to IEEE 112 std. - method ?B? or C390 CSA

    All WEG motors are energy efficiency verified by UL in addition to the DOE.







    CSA and UL approved




    ALSO ENERGY VERIFIED CSA C390-93(+)
    CSA approved - File LR 50962
    Division I, class I, groups C and D
    Division I, class II, groups F and G

    UL approved - File E 87848
    Temperature code T4
    Frame 143T up to 326T
    Division I, class I, groups C and D
    Division I, class II, grops F and G

    Frame 364T up to 505
    Temperature code T3C
    Division I, class I, groups C and D
    Division I, class II, groups F and G (for group G, Service Factor 1.0)

    Frame 586/7
    Temperature code T3C
    Division I, class I, groups C and D
    Division I, class II, group F